TGS1820
|
MOS |
- High sensitivity and selectivity to acetone |
Acetone |
1 - 20 ppm |
VC: 2.3V
(PD:125mv ave.)
|
5.9~12.35
0.7g
approx.
|
TGS2600
|
MOS |
- High sensitivity to total air
contaminants |
Air
pollutants |
Hydrogen
1 - 30 ppm |
VH: 5.0V
VC: 5.0V
(PD: 210mW)
|
9.2~7.8
1.1g
approx.
|
TGS2602
|
MOS |
- High sensitivity to VOCs,
ammonia and H2S |
Air
pollutants |
Ethanol
1 - 30 ppm |
VH: 5.0V
VC: 5.0V
(PD: 280mW)
|
9.2~7.8
1.1g
approx.
|
TGS2603
|
MOS |
- High sensitivity to amine and
sulfur series odor
(Trimethylamine,
methyl mercaptan, etc.) |
Air
pollutants |
Ethanol
1 - 10ppm |
VH: 5.0V
VC: 5.0V
(PD: 240mW)
|
9.2~7.8
1.1g
aprrox.
|
TGS2610-C00
|
MOS |
- Quick response to LP gas |
Butane
Propane |
1 - 25 %LEL |
VH: 5.0V
VC: 5.0V
(PD: 280mW)
|
9.2~7.8
1.2g
approx.
|
TGS2610-D00
|
MOS |
- Selective response for LP gas
with built-in filter |
Butane
Propane |
1 - 25 %LEL |
VH: 5.0V
VC: 5.0V
(PD: 280mW)
|
9.2~12.4
1.4g
approx.
|
TGS2611-C00
|
MOS |
- Quick response to methane |
Methane |
1 - 25 %LEL |
VH: 5.0V
VC: 5.0V
(PD: 280mW)
|
9.2~7.8
1.2g
approx.
|
TGS2611-E00
|
MOS |
- Selective response for
methane with built-in filter |
Methane |
1 - 25 %LEL |
VH: 5.0V
VC: 5.0V
(PD: 280mW)
|
9.2~12.4
1.4g
approx.
|
TGS2612-D00
|
MOS |
- Comparable response to %LEL
of methane and LP gas |
Methane
Propane
Butane |
1 - 25 %LEL |
VH: 5.0V
VC: 5.0V
(PD: 280mW)
|
9.2~12.4
1.4g
approx.
|
TGS2616-C00
|
MOS |
- High selectivity to hydrogen |
Hydrogen |
30 -
3,000 ppm |
VH: 5.0V
VC: 5.0V
(PD: 280mW)
|
9.2~7.8
1.2g
approx.
|
TGS2620
|
MOS |
- High sensitivity to organic
solvent vapors |
Alcohol
Solvent
vapors |
50 -
5,000 ppm |
VH: 5.0V
VC: 5.0V
(PD: 210mW)
|
9.2~7.8
1.2g
approx.
|
TGS2630
|
MOS |
- High sensitivity to low-
flammable refrigerant gases |
Refrigerant
gases |
1,000 -
10,000 ppm |
VH: 5.0V
VC: 5.0V
(PD: 280mW)
|
9.2~12.4
1.4g
approx.
|
TGS3830
|
MOS |
- High sensitivity to refrigerant
gases
- Quick response
- Low power consumption |
Halocarbon
gas |
5 - 100 ppm |
VH: 0.8V}3%
VC: 5.0V
(PD: 100mW)
|
9.2~8.5
1.1g
approx.
|
TGS3870
|
MOS |
- Dual gas detection for both
methane and CO |
Methane
CO |
Methane
1 - 25 %LEL
CO
50 -
1,000 ppm |
VH:
VHH 0.9V(5sec.)
VHL 0.2V(15sec.)
VC: 5.0V pulse
(PD:38mv ave.)
|
9.2~13.0
1.1g
approx.
|
TGS8410
|
MOS |
- Low power consumption
- Battery operable
- High selectivity to Methane |
Methane |
1 - 25 %LEL |
VH:
VHH 1.9V(0.1sec.)
VHL 0.0V(29.9sec.)
VC: 2.0V pulse
(PD:0.087mv ave.)
|
9.2~12.5
1.4g
approx.
|
TGS5042-A00
|
EC |
- High repeatability/selectivity
to CO
- Sensitivity data bar code on
each sensor |
CO |
0 -
10,000 ppm |
(PD: 0mW)
|
14.1~49.7
12g
approx.
|
TGS5141-P00
|
EC |
- Compact
- Sensitivity data bar code on
each sensor |
CO |
0 -
5,000 ppm |
(PD: 0mW)
|
14.6~13.9
~6.8
2.5g
approx.
|
TGS6810-D00
|
CAT |
- Linear output over a wide
detection range |
Methane
Propane
Butane |
0 - 100 %LEL |
VC: 3.0V
(PD: 525mW)
|
12.0~13.0
1.5g
approx.
|
CDM7162-C00
|
NDIR |
- High accuracy
- Compact
- CO2 level output |
CO2 |
360 -
5,000 ppm |
VIN: 3.3V or 5.0V
(PD: 125mW ave.@5VDC)
|
32x17x8
3g
approx.
|